fix
zhangqian
2023-10-19 cab6eea89a0d82710369604ecb51f1cdb122e433
service/plc.go
@@ -1,78 +1,154 @@
package service
import (
   "apsClient/conf"
   "apsClient/constvar"
   "apsClient/model"
   "apsClient/pkg/logx"
   "apsClient/pkg/plc"
   "apsClient/pkg/plc/apacheplc4x"
   "apsClient/pkg/plc/modbusx"
   "apsClient/pkg/plccom"
   "encoding/binary"
   "errors"
   "fmt"
   "github.com/spf13/cast"
)
func PlcRead(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType) (val interface{}, err error) {
func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) {
   var (
      startAddress int
      valueType    constvar.PlcStartAddressValueType
      dataLength   int
      ipAddr       string
   )
   if plcConfig.CurrentTryTimes > plcConfig.MaxTryTimes {
      return plcConfig.CurrentErr
   }
   plcConfig.CurrentTryTimes++
   for _, pc := range plcConfig.Details {
      if pc.FieldName == fieldType {
      if pc.FieldName == fieldType && pc.Channel == channel {
         startAddress = pc.StartAddress
         valueType = pc.Type
         dataLength = pc.Length
      }
   }
   if plcConfig.Method == constvar.PlcMethodModbusTCP {
      ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
   }
      err = WriteHoldingRegister(ipAddr, startAddress, value)
   conn, err := plc.NewModbusConnection(ipAddr)
   if err != nil {
      logx.Errorf("GetProductProgress 连接plc失败: %v", err.Error())
      return
      if err != nil {
         logx.Errorf("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error())
         plcConfig.CurrentErr = err
         return PlcWrite(plcConfig, fieldType, channel, value)
      }
      logx.Infof("plc write ok, address: %v, value: %v", startAddress, value)
   } else if plcConfig.Method == constvar.PlcMethodSerial {
      ipAddr = conf.Conf.Services.Serial
      if ipAddr == "" {
         return errors.New("conf.Conf.Services.Serial config not set yet")
      }
      label := fmt.Sprintf("D%d", startAddress)
      return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value))
   }
   defer conn.Close()
   rawData, err := plc.ReadHoldingRegister(conn, startAddress, dataLength)
   if err != nil {
      logx.Errorf("GetProductProgress 获取plc数据失败: %v", err.Error())
      return
   }
   switch valueType {
   case constvar.PlcStartAddressValueTypeString:
      return string(rawData), nil
   case constvar.PlcStartAddressValueTypeInt:
      return int(binary.BigEndian.Uint16(rawData)), nil
   }
   return nil, errors.New("undefined value type")
   return
}
func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, value interface{}) (err error) {
func PlcWriteDirect(plcConfig *model.DevicePlc, address int, value interface{}) (err error) {
   var (
      startAddress int
      ipAddr       string
      ipAddr string
   )
   for _, pc := range plcConfig.Details {
      if pc.FieldName == fieldType {
         startAddress = pc.StartAddress
      }
   if plcConfig.Method == constvar.PlcMethodModbusTCP {
      ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
   }
      err = WriteHoldingRegister(ipAddr, address, value)
   conn, err := plc.NewModbusConnection(ipAddr)
   if err != nil {
      logx.Errorf("GetProductProgress 连接plc失败: %v", err.Error())
      return
      if err != nil {
         logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error())
         return err
      }
      logx.Infof("plc write ok, address: %v, value: %v", address, value)
   } else if plcConfig.Method == constvar.PlcMethodSerial {
      ipAddr = conf.Conf.Services.Serial
      if ipAddr == "" {
         return errors.New("conf.Conf.Services.Serial config not set yet")
      }
      label := fmt.Sprintf("D%d", address)
      return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value))
   }
   defer conn.Close()
   result, err := plc.WriteHoldingRegister(conn, startAddress, value)
   if err != nil {
      logx.Infof("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error())
      return
   }
   logx.Infof("plc write ok, address: %v, value: %v, result: %v", startAddress, value, result)
   return
}
func PlcReadDirect(plcConfig *model.DevicePlc, address int, dataLength int, valueType constvar.PlcStartAddressValueType) (val interface{}, err error) {
   var (
      ipAddr string
   )
   if plcConfig.Method == constvar.PlcMethodModbusTCP {
      ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
      value, err := ReadHoldingRegister(ipAddr, address, dataLength)
      if err != nil {
         return nil, err
      }
      switch valueType {
      case constvar.PlcStartAddressValueTypeString:
         return string(value), nil
      case constvar.PlcStartAddressValueTypeInt:
         if len(value) == 2 {
            val = binary.BigEndian.Uint16(value)
         } else if len(value) == 4 {
            val = binary.BigEndian.Uint32(value)
         } else {
            logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address)
            return nil, errors.New(fmt.Sprintf("unknown int value:%v", value))
         }
      }
      logx.Infof("plc read ok, address: %v, result: %v", address, val)
      return val, nil
   } else if plcConfig.Method == constvar.PlcMethodSerial {
      ipAddr = conf.Conf.Services.Serial
      if ipAddr == "" {
         return nil, errors.New("conf.Conf.Services.Serial config not set yet")
      }
      label := fmt.Sprintf("D%d", address)
      return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label)
   }
   return
}
func ReadHoldingRegister(ipAddr string, address, length int) ([]byte, error) {
   if conf.Conf.PLC.Package == constvar.PlcPackageApache {
      return apacheplc4x.ReadHoldingRegister(ipAddr, address, length)
   } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection {
      conn, err := plc.GetModbusConnection(ipAddr)
      if err != nil {
         return nil, err
      }
      return plc.ReadHoldingRegister(conn, address, length)
   } else {
      return modbusx.Read(ipAddr, uint16(address), uint16(length))
   }
}
func WriteHoldingRegister(ipAddr string, address int, value any) (err error) {
   if conf.Conf.PLC.Package == constvar.PlcPackageApache {
      _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value)
      return err
   } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection {
      conn, err := plc.GetModbusConnection(ipAddr)
      if err != nil {
         return err
      }
      _, err = plc.WriteHoldingRegister(conn, address, value)
      return err
   } else {
      return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value))
   }
}
func PlcIsConnect() bool {
   if conf.Conf.PLC.Package == constvar.PlcPackageApache {
      return apacheplc4x.IsConnect()
   } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection {
      return false
   } else {
      return modbusx.IsConnect()
   }
}