| | | package service |
| | | |
| | | import ( |
| | | "apsClient/conf" |
| | | "apsClient/constvar" |
| | | "apsClient/model" |
| | | "apsClient/model/common" |
| | | "apsClient/pkg/logx" |
| | | "apsClient/pkg/plc" |
| | | "apsClient/pkg/plc/apacheplc4x" |
| | | "apsClient/pkg/plc/modbusx" |
| | | "apsClient/pkg/plccom" |
| | | "encoding/binary" |
| | | "errors" |
| | | "fmt" |
| | | "github.com/spf13/cast" |
| | | "sync" |
| | | ) |
| | | |
| | | func PlcRead(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType) (val interface{}, err error) { |
| | | // 串口不支持并行读写,所以需要加个锁,防止timeout和资源不可用报错 |
| | | var lock sync.Mutex |
| | | |
| | | func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) { |
| | | var ( |
| | | startAddress int |
| | | valueType constvar.PlcStartAddressValueType |
| | | dataLength int |
| | | ipAddr string |
| | | ) |
| | | |
| | | if plcConfig.CurrentTryTimes > plcConfig.MaxTryTimes { |
| | | return plcConfig.CurrentErr |
| | | } |
| | | plcConfig.CurrentTryTimes++ |
| | | |
| | | for _, pc := range plcConfig.Details { |
| | | if pc.FieldName == fieldType { |
| | | if pc.FieldName == fieldType && pc.Channel == channel { |
| | | startAddress = pc.StartAddress |
| | | valueType = pc.Type |
| | | dataLength = pc.Length |
| | | } |
| | | } |
| | | ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) |
| | | |
| | | conn, err := plc.GetModbusConnection(ipAddr) |
| | | if err != nil { |
| | | logx.Errorf("PlcRead 连接plc失败: %v", err.Error()) |
| | | return |
| | | } |
| | | |
| | | rawData, err := plc.ReadHoldingRegister(conn, startAddress, dataLength) |
| | | if err != nil { |
| | | logx.Errorf("PlcRead 获取plc数据失败: %v", err.Error()) |
| | | return |
| | | } |
| | | switch valueType { |
| | | case constvar.PlcStartAddressValueTypeString: |
| | | return string(rawData), nil |
| | | case constvar.PlcStartAddressValueTypeInt: |
| | | return int(binary.BigEndian.Uint16(rawData)), nil |
| | | } |
| | | return nil, errors.New("undefined value type") |
| | | return PlcWriteDirect(plcConfig, startAddress, value) |
| | | } |
| | | |
| | | func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, value interface{}) (err error) { |
| | | func PlcWriteDirect(plcConfig *model.DevicePlc, address int, value interface{}) (err error) { |
| | | lock.Lock() |
| | | defer lock.Unlock() |
| | | var ( |
| | | startAddress int |
| | | ipAddr string |
| | | ipAddr string |
| | | ) |
| | | defer func() { |
| | | dealErr(err) |
| | | }() |
| | | if plcConfig.Method == constvar.PlcMethodModbusTCP { |
| | | ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) |
| | | err = WriteByModbusTCP(ipAddr, address, value) |
| | | |
| | | for _, pc := range plcConfig.Details { |
| | | if pc.FieldName == fieldType { |
| | | startAddress = pc.StartAddress |
| | | if err != nil { |
| | | logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error()) |
| | | return err |
| | | } |
| | | } |
| | | ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) |
| | | logx.Infof("plc write ok, address: %v, value: %v", address, value) |
| | | } else if plcConfig.Method == constvar.PlcMethodModbusRTU { |
| | | ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) |
| | | err = WriteByModbusRTU(plcConfig, address, value) |
| | | |
| | | conn, err := plc.GetModbusConnection(ipAddr) |
| | | if err != nil { |
| | | logx.Errorf("PlcWrite 连接plc失败: %v", err.Error()) |
| | | return |
| | | if err != nil { |
| | | logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error()) |
| | | return err |
| | | } |
| | | logx.Infof("plc write ok, address: %v, value: %v", address, value) |
| | | } else if plcConfig.Method == constvar.PlcMethodSerial { |
| | | ipAddr = conf.Conf.Services.Serial |
| | | if ipAddr == "" { |
| | | return errors.New("conf.Conf.Services.Serial config not set yet") |
| | | } |
| | | label := fmt.Sprintf("D%d", address) |
| | | return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value)) |
| | | } |
| | | |
| | | result, err := plc.WriteHoldingRegister(conn, startAddress, value) |
| | | if err != nil { |
| | | logx.Infof("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error()) |
| | | return |
| | | } |
| | | logx.Infof("plc write ok, address: %v, value: %v, result: %v", startAddress, value, result) |
| | | return |
| | | } |
| | | |
| | | type CacheStore struct { |
| | | cache map[string]interface{} |
| | | mu sync.Mutex |
| | | func PlcReadDirect(plcConfig *model.DevicePlc, address int, dataLength int, valueType constvar.PlcStartAddressValueType) (val interface{}, err error) { |
| | | lock.Lock() |
| | | defer lock.Unlock() |
| | | var ( |
| | | ipAddr string |
| | | ) |
| | | defer func() { |
| | | dealErr(err) |
| | | }() |
| | | if plcConfig.Method == constvar.PlcMethodModbusTCP || plcConfig.Method == constvar.PlcMethodModbusRTU { |
| | | var value []byte |
| | | if plcConfig.Method == constvar.PlcMethodModbusTCP { |
| | | ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) |
| | | value, err = ReadByModbusTCP(ipAddr, address, dataLength) |
| | | if err != nil { |
| | | return nil, err |
| | | } |
| | | } else { |
| | | value, err = ReadByModbusRTU(plcConfig, address, dataLength) |
| | | if err != nil { |
| | | return nil, err |
| | | } |
| | | } |
| | | |
| | | switch valueType { |
| | | case constvar.PlcStartAddressValueTypeString: |
| | | return string(value), nil |
| | | case constvar.PlcStartAddressValueTypeInt32: |
| | | if len(value) == 2 { |
| | | val = binary.BigEndian.Uint16(value) |
| | | } else if len(value) == 4 { |
| | | val = binary.BigEndian.Uint32(value) |
| | | } else { |
| | | logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address) |
| | | return nil, errors.New(fmt.Sprintf("unknown int value:%v", value)) |
| | | } |
| | | default: |
| | | if len(value) == 2 { |
| | | val = binary.BigEndian.Uint16(value) |
| | | } else if len(value) == 4 { |
| | | low16Val := uint32(binary.BigEndian.Uint16(value[:2])) |
| | | high16 := uint32(binary.BigEndian.Uint16(value[2:])) << 16 |
| | | val = low16Val + high16 |
| | | } else { |
| | | logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address) |
| | | return nil, errors.New(fmt.Sprintf("unknown int value:%v", value)) |
| | | } |
| | | } |
| | | logx.Infof("plc read ok, address: %v, result: %v, dataLength: %v, value: %v", address, val, dataLength, value) |
| | | return val, nil |
| | | } else if plcConfig.Method == constvar.PlcMethodSerial { |
| | | ipAddr = conf.Conf.Services.Serial |
| | | if ipAddr == "" { |
| | | return nil, errors.New("conf.Conf.Services.Serial config not set yet") |
| | | } |
| | | label := fmt.Sprintf("D%d", address) |
| | | return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label, dataLength) |
| | | } |
| | | return |
| | | } |
| | | |
| | | var defaultCacheStore *CacheStore |
| | | |
| | | func init() { |
| | | defaultCacheStore = newCacheManager() |
| | | } |
| | | func newCacheManager() *CacheStore { |
| | | return &CacheStore{ |
| | | cache: make(map[string]interface{}), |
| | | func ReadByModbusTCP(ipAddr string, address, length int) ([]byte, error) { |
| | | if conf.Conf.PLC.Package == constvar.PlcPackageApache { |
| | | return apacheplc4x.ReadHoldingRegister(ipAddr, address, length) |
| | | } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { |
| | | conn, err := plc.GetModbusConnection(ipAddr) |
| | | if err != nil { |
| | | return nil, err |
| | | } |
| | | return plc.ReadHoldingRegister(conn, address, length) |
| | | } else { |
| | | return modbusx.Read(ipAddr, uint16(address), uint16(length)) |
| | | } |
| | | } |
| | | |
| | | func (cm *CacheStore) Get(key string) (interface{}, bool) { |
| | | cm.mu.Lock() |
| | | defer cm.mu.Unlock() |
| | | |
| | | conn, ok := cm.cache[key] |
| | | return conn, ok |
| | | func WriteByModbusTCP(ipAddr string, address int, value any) (err error) { |
| | | if conf.Conf.PLC.Package == constvar.PlcPackageApache { |
| | | _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value) |
| | | return err |
| | | } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { |
| | | conn, err := plc.GetModbusConnection(ipAddr) |
| | | if err != nil { |
| | | return err |
| | | } |
| | | _, err = plc.WriteHoldingRegister(conn, address, value) |
| | | return err |
| | | } else { |
| | | return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value)) |
| | | } |
| | | } |
| | | |
| | | func (cm *CacheStore) Add(key string, value interface{}) { |
| | | cm.mu.Lock() |
| | | defer cm.mu.Unlock() |
| | | cm.cache[key] = value |
| | | func ReadByModbusRTU(plcConfig *model.DevicePlc, address, length int) ([]byte, error) { |
| | | rtuConfig := &common.RTUConfig{ |
| | | BaudRate: plcConfig.BaudRate, |
| | | SerialName: plcConfig.SerialName, |
| | | DataBit: plcConfig.DataBit, |
| | | StopBit: plcConfig.StopBit, |
| | | Parity: plcConfig.Parity, |
| | | } |
| | | if conf.Conf.PLC.Package == constvar.PlcPackageApache { |
| | | return apacheplc4x.ReadHoldingRegisterByRTU(rtuConfig, address, length) |
| | | } else { |
| | | return modbusx.ReadByRTU(rtuConfig, uint16(address), uint16(length)) |
| | | } |
| | | } |
| | | |
| | | func PlcCacheGet(key string) (interface{}, bool) { |
| | | return defaultCacheStore.Get(key) |
| | | func WriteByModbusRTU(plcConfig *model.DevicePlc, address int, value any) (err error) { |
| | | rtuConfig := &common.RTUConfig{ |
| | | BaudRate: plcConfig.BaudRate, |
| | | SerialName: plcConfig.SerialName, |
| | | DataBit: plcConfig.DataBit, |
| | | StopBit: plcConfig.StopBit, |
| | | Parity: plcConfig.Parity, |
| | | } |
| | | if conf.Conf.PLC.Package == constvar.PlcPackageApache { |
| | | _, err = apacheplc4x.WriteHoldingRegisterByRTU(rtuConfig, address, value) |
| | | return err |
| | | } else { |
| | | return modbusx.WriteByRTU(rtuConfig, uint16(address), cast.ToInt(value)) |
| | | } |
| | | } |
| | | |
| | | func PlcCacheSet(key string, value interface{}) { |
| | | defaultCacheStore.Add(key, value) |
| | | func PlcIsConnect() bool { |
| | | return IsConnect() |
| | | } |
| | | |
| | | func dealErr(err error) { |
| | | if err != nil { |
| | | FailureRemainingOpportunitiesDecr() //减少失败剩余机会 |
| | | } else { |
| | | FailureRemainingOpportunitiesReset() //重置失败剩余机会 |
| | | } |
| | | } |
| | | |
| | | var connectionStatus sync.Map |
| | | |
| | | const ( |
| | | defaultFailureRemainingOpportunities = 20 |
| | | ) |
| | | |
| | | func IsConnect() bool { |
| | | val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) |
| | | if !ok { |
| | | return false |
| | | } |
| | | failureRemainingOpportunities := val.(int) |
| | | return failureRemainingOpportunities > 0 |
| | | } |
| | | |
| | | func FailureRemainingOpportunitiesDecr() { |
| | | val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) |
| | | if !ok { |
| | | return |
| | | } |
| | | failureRemainingOpportunities := val.(int) |
| | | if failureRemainingOpportunities > 0 { |
| | | failureRemainingOpportunities-- |
| | | } |
| | | connectionStatus.Store(conf.Conf.CurrentDeviceID, failureRemainingOpportunities) |
| | | return |
| | | } |
| | | |
| | | func FailureRemainingOpportunitiesReset() { |
| | | val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) |
| | | if !ok || val.(int) < defaultFailureRemainingOpportunities { |
| | | connectionStatus.Store(conf.Conf.CurrentDeviceID, defaultFailureRemainingOpportunities) |
| | | return |
| | | } |
| | | return |
| | | } |