From cab6eea89a0d82710369604ecb51f1cdb122e433 Mon Sep 17 00:00:00 2001 From: zhangqian <zhangqian@123.com> Date: 星期四, 19 十月 2023 17:26:34 +0800 Subject: [PATCH] fix --- service/plc.go | 92 ++++++++++++++++++++++++++------------------- 1 files changed, 53 insertions(+), 39 deletions(-) diff --git a/service/plc.go b/service/plc.go index e2a3990..f73ec58 100644 --- a/service/plc.go +++ b/service/plc.go @@ -5,7 +5,9 @@ "apsClient/constvar" "apsClient/model" "apsClient/pkg/logx" + "apsClient/pkg/plc" "apsClient/pkg/plc/apacheplc4x" + "apsClient/pkg/plc/modbusx" "apsClient/pkg/plccom" "encoding/binary" "errors" @@ -13,7 +15,7 @@ "github.com/spf13/cast" ) -func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, position int, value interface{}) (err error) { +func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) { var ( startAddress int ipAddr string @@ -25,30 +27,19 @@ plcConfig.CurrentTryTimes++ for _, pc := range plcConfig.Details { - if pc.FieldName == fieldType && pc.Position == position { + if pc.FieldName == fieldType && pc.Channel == channel { startAddress = pc.StartAddress } } if plcConfig.Method == constvar.PlcMethodModbusTCP { ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - //conn, err := plc.GetModbusConnection(ipAddr) - //if err != nil { - // logx.Errorf("plc write failed, 杩炴帴plc澶辫触: %v", err.Error()) - // plcConfig.CurrentErr = err - // return PlcWrite(plcConfig, fieldType, position, value) - //} - // - //result, err := plc.WriteHoldingRegister(conn, startAddress, value) - - //err = modbusx.Write(ipAddr, uint16(startAddress), value) - - _, err = apacheplc4x.WriteHoldingRegister(ipAddr, startAddress, value) + err = WriteHoldingRegister(ipAddr, startAddress, value) if err != nil { logx.Errorf("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error()) plcConfig.CurrentErr = err - return PlcWrite(plcConfig, fieldType, position, value) + return PlcWrite(plcConfig, fieldType, channel, value) } logx.Infof("plc write ok, address: %v, value: %v", startAddress, value) } else if plcConfig.Method == constvar.PlcMethodSerial { @@ -68,17 +59,7 @@ ) if plcConfig.Method == constvar.PlcMethodModbusTCP { ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - //conn, err := plc.GetModbusConnection(ipAddr) - //if err != nil { - // logx.Errorf("plc write failed, 杩炴帴plc澶辫触: %v", err.Error()) - // plcConfig.CurrentErr = err - // return PlcWriteDirect(plcConfig, address, value) - //} - //result, err := plc.WriteHoldingRegister(conn, address, value) - - //err = modbusx.Write(ipAddr, uint16(address), value) - - _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value) + err = WriteHoldingRegister(ipAddr, address, value) if err != nil { logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error()) @@ -102,17 +83,7 @@ ) if plcConfig.Method == constvar.PlcMethodModbusTCP { ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - //conn, err := plc.GetModbusConnection(ipAddr) - //if err != nil { - // plcConfig.CurrentErr = err - // return PlcReadDirect(plcConfig, address, dataLength, valueType) - //} - //value, err := plc.ReadHoldingRegister(conn, address, dataLength) - - //value, err := modbusx.Read(ipAddr, uint16(address), uint16(dataLength)) - - value, err := apacheplc4x.ReadHoldingRegister(ipAddr, address, dataLength) - + value, err := ReadHoldingRegister(ipAddr, address, dataLength) if err != nil { return nil, err } @@ -121,13 +92,16 @@ return string(value), nil case constvar.PlcStartAddressValueTypeInt: if len(value) == 2 { - return int(binary.BigEndian.Uint16(value)), nil + val = binary.BigEndian.Uint16(value) + } else if len(value) == 4 { + val = binary.BigEndian.Uint32(value) } else { logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address) return nil, errors.New(fmt.Sprintf("unknown int value锛�%v", value)) } } - logx.Infof("plc read ok, address: %v, result: %v", address, value) + logx.Infof("plc read ok, address: %v, result: %v", address, val) + return val, nil } else if plcConfig.Method == constvar.PlcMethodSerial { ipAddr = conf.Conf.Services.Serial if ipAddr == "" { @@ -138,3 +112,43 @@ } return } + +func ReadHoldingRegister(ipAddr string, address, length int) ([]byte, error) { + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + return apacheplc4x.ReadHoldingRegister(ipAddr, address, length) + } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { + conn, err := plc.GetModbusConnection(ipAddr) + if err != nil { + return nil, err + } + return plc.ReadHoldingRegister(conn, address, length) + } else { + return modbusx.Read(ipAddr, uint16(address), uint16(length)) + } +} + +func WriteHoldingRegister(ipAddr string, address int, value any) (err error) { + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value) + return err + } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { + conn, err := plc.GetModbusConnection(ipAddr) + if err != nil { + return err + } + _, err = plc.WriteHoldingRegister(conn, address, value) + return err + } else { + return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value)) + } +} + +func PlcIsConnect() bool { + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + return apacheplc4x.IsConnect() + } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { + return false + } else { + return modbusx.IsConnect() + } +} -- Gitblit v1.8.0