From 8324f872ef3a4d0c978a9b1d062800c6a1701c12 Mon Sep 17 00:00:00 2001 From: zhangqian <zhangqian@123.com> Date: 星期五, 01 十二月 2023 09:58:17 +0800 Subject: [PATCH] fix --- service/plc.go | 280 ++++++++++++++++++++++++++++++++++++++++--------------- 1 files changed, 204 insertions(+), 76 deletions(-) diff --git a/service/plc.go b/service/plc.go index d5b8126..c577998 100644 --- a/service/plc.go +++ b/service/plc.go @@ -1,120 +1,248 @@ package service import ( + "apsClient/conf" "apsClient/constvar" "apsClient/model" + "apsClient/model/common" "apsClient/pkg/logx" "apsClient/pkg/plc" + "apsClient/pkg/plc/apacheplc4x" + "apsClient/pkg/plc/modbusx" + "apsClient/pkg/plccom" "encoding/binary" "errors" "fmt" + "github.com/spf13/cast" "sync" ) -func PlcRead(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType) (val interface{}, err error) { +// 涓插彛涓嶆敮鎸佸苟琛岃鍐欙紝鎵�浠ラ渶瑕佸姞涓攣锛岄槻姝imeout鍜岃祫婧愪笉鍙敤鎶ラ敊 +var lock sync.Mutex + +func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) { var ( startAddress int - valueType constvar.PlcStartAddressValueType - dataLength int - ipAddr string ) + if plcConfig.CurrentTryTimes > plcConfig.MaxTryTimes { + return plcConfig.CurrentErr + } + plcConfig.CurrentTryTimes++ + for _, pc := range plcConfig.Details { - if pc.FieldName == fieldType { + if pc.FieldName == fieldType && pc.Channel == channel { startAddress = pc.StartAddress - valueType = pc.Type - dataLength = pc.Length } } - ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - - conn, err := plc.GetModbusConnection(ipAddr) - if err != nil { - logx.Errorf("PlcRead 杩炴帴plc澶辫触: %v", err.Error()) - return - } - - rawData, err := plc.ReadHoldingRegister(conn, startAddress, dataLength) - if err != nil { - logx.Errorf("PlcRead 鑾峰彇plc鏁版嵁澶辫触: %v", err.Error()) - return - } - switch valueType { - case constvar.PlcStartAddressValueTypeString: - return string(rawData), nil - case constvar.PlcStartAddressValueTypeInt: - if len(rawData) == 2 { - return int(binary.BigEndian.Uint16(rawData)), nil - } else { - logx.Errorf("plc read get an unknown int value: %v, address:%v", rawData, startAddress) - return nil, errors.New(fmt.Sprintf("unknown int value锛�%v", rawData)) - } - } - return nil, errors.New("undefined value type") + return PlcWriteDirect(plcConfig, startAddress, value) } -func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, value interface{}) (err error) { +func PlcWriteDirect(plcConfig *model.DevicePlc, address int, value interface{}) (err error) { + lock.Lock() + defer lock.Unlock() var ( - startAddress int - ipAddr string + ipAddr string ) + defer func() { + dealErr(err) + }() + if plcConfig.Method == constvar.PlcMethodModbusTCP { + ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) + err = WriteByModbusTCP(ipAddr, address, value) - for _, pc := range plcConfig.Details { - if pc.FieldName == fieldType { - startAddress = pc.StartAddress + if err != nil { + logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error()) + return err } - } - ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) + logx.Infof("plc write ok, address: %v, value: %v", address, value) + } else if plcConfig.Method == constvar.PlcMethodModbusRTU { + ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) + err = WriteByModbusRTU(plcConfig, address, value) - conn, err := plc.GetModbusConnection(ipAddr) - if err != nil { - logx.Errorf("PlcWrite 杩炴帴plc澶辫触: %v", err.Error()) - return + if err != nil { + logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error()) + return err + } + logx.Infof("plc write ok, address: %v, value: %v", address, value) + } else if plcConfig.Method == constvar.PlcMethodSerial { + ipAddr = conf.Conf.Services.Serial + if ipAddr == "" { + return errors.New("conf.Conf.Services.Serial config not set yet") + } + label := fmt.Sprintf("D%d", address) + return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value)) } - - result, err := plc.WriteHoldingRegister(conn, startAddress, value) - if err != nil { - logx.Infof("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error()) - return - } - logx.Infof("plc write ok, address: %v, value: %v, result: %v", startAddress, value, result) return } -type CacheStore struct { - cache map[string]interface{} - mu sync.Mutex +func PlcReadDirect(plcConfig *model.DevicePlc, address int, dataLength int, valueType constvar.PlcStartAddressValueType) (val interface{}, err error) { + lock.Lock() + defer lock.Unlock() + var ( + ipAddr string + ) + defer func() { + dealErr(err) + }() + if plcConfig.Method == constvar.PlcMethodModbusTCP || plcConfig.Method == constvar.PlcMethodModbusRTU { + var value []byte + if plcConfig.Method == constvar.PlcMethodModbusTCP { + ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) + value, err = ReadByModbusTCP(ipAddr, address, dataLength) + if err != nil { + return nil, err + } + } else { + value, err = ReadByModbusRTU(plcConfig, address, dataLength) + if err != nil { + return nil, err + } + } + + switch valueType { + case constvar.PlcStartAddressValueTypeString: + return string(value), nil + case constvar.PlcStartAddressValueTypeInt32: + if len(value) == 2 { + val = binary.BigEndian.Uint16(value) + } else if len(value) == 4 { + val = binary.BigEndian.Uint32(value) + } else { + logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address) + return nil, errors.New(fmt.Sprintf("unknown int value锛�%v", value)) + } + default: + if len(value) == 2 { + val = binary.BigEndian.Uint16(value) + } else if len(value) == 4 { + low16Val := uint32(binary.BigEndian.Uint16(value[:2])) + high16 := uint32(binary.BigEndian.Uint16(value[2:])) << 16 + val = low16Val + high16 + } else { + logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address) + return nil, errors.New(fmt.Sprintf("unknown int value锛�%v", value)) + } + } + logx.Infof("plc read ok, address: %v, result: %v, dataLength: %v, value: %v", address, val, dataLength, value) + return val, nil + } else if plcConfig.Method == constvar.PlcMethodSerial { + ipAddr = conf.Conf.Services.Serial + if ipAddr == "" { + return nil, errors.New("conf.Conf.Services.Serial config not set yet") + } + label := fmt.Sprintf("D%d", address) + return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label, dataLength) + } + return } -var defaultCacheStore *CacheStore - -func init() { - defaultCacheStore = newCacheManager() -} -func newCacheManager() *CacheStore { - return &CacheStore{ - cache: make(map[string]interface{}), +func ReadByModbusTCP(ipAddr string, address, length int) ([]byte, error) { + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + return apacheplc4x.ReadHoldingRegister(ipAddr, address, length) + } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { + conn, err := plc.GetModbusConnection(ipAddr) + if err != nil { + return nil, err + } + return plc.ReadHoldingRegister(conn, address, length) + } else { + return modbusx.Read(ipAddr, uint16(address), uint16(length)) } } -func (cm *CacheStore) Get(key string) (interface{}, bool) { - cm.mu.Lock() - defer cm.mu.Unlock() - - conn, ok := cm.cache[key] - return conn, ok +func WriteByModbusTCP(ipAddr string, address int, value any) (err error) { + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value) + return err + } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { + conn, err := plc.GetModbusConnection(ipAddr) + if err != nil { + return err + } + _, err = plc.WriteHoldingRegister(conn, address, value) + return err + } else { + return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value)) + } } -func (cm *CacheStore) Add(key string, value interface{}) { - cm.mu.Lock() - defer cm.mu.Unlock() - cm.cache[key] = value +func ReadByModbusRTU(plcConfig *model.DevicePlc, address, length int) ([]byte, error) { + rtuConfig := &common.RTUConfig{ + BaudRate: plcConfig.BaudRate, + SerialName: plcConfig.SerialName, + DataBit: plcConfig.DataBit, + StopBit: plcConfig.StopBit, + Parity: plcConfig.Parity, + } + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + return apacheplc4x.ReadHoldingRegisterByRTU(rtuConfig, address, length) + } else { + return modbusx.ReadByRTU(rtuConfig, uint16(address), uint16(length)) + } } -func PlcCacheGet(key string) (interface{}, bool) { - return defaultCacheStore.Get(key) +func WriteByModbusRTU(plcConfig *model.DevicePlc, address int, value any) (err error) { + rtuConfig := &common.RTUConfig{ + BaudRate: plcConfig.BaudRate, + SerialName: plcConfig.SerialName, + DataBit: plcConfig.DataBit, + StopBit: plcConfig.StopBit, + Parity: plcConfig.Parity, + } + if conf.Conf.PLC.Package == constvar.PlcPackageApache { + _, err = apacheplc4x.WriteHoldingRegisterByRTU(rtuConfig, address, value) + return err + } else { + return modbusx.WriteByRTU(rtuConfig, uint16(address), cast.ToInt(value)) + } } -func PlcCacheSet(key string, value interface{}) { - defaultCacheStore.Add(key, value) +func PlcIsConnect() bool { + return IsConnect() +} + +func dealErr(err error) { + if err != nil { + FailureRemainingOpportunitiesDecr() //鍑忓皯澶辫触鍓╀綑鏈轰細 + } else { + FailureRemainingOpportunitiesReset() //閲嶇疆澶辫触鍓╀綑鏈轰細 + } +} + +var connectionStatus sync.Map + +const ( + defaultFailureRemainingOpportunities = 20 +) + +func IsConnect() bool { + val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) + if !ok { + return false + } + failureRemainingOpportunities := val.(int) + return failureRemainingOpportunities > 0 +} + +func FailureRemainingOpportunitiesDecr() { + val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) + if !ok { + return + } + failureRemainingOpportunities := val.(int) + if failureRemainingOpportunities > 0 { + failureRemainingOpportunities-- + } + connectionStatus.Store(conf.Conf.CurrentDeviceID, failureRemainingOpportunities) + return +} + +func FailureRemainingOpportunitiesReset() { + val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) + if !ok || val.(int) < defaultFailureRemainingOpportunities { + connectionStatus.Store(conf.Conf.CurrentDeviceID, defaultFailureRemainingOpportunities) + return + } + return } -- Gitblit v1.8.0