From 2d6875c93b25d0b7336c7fa11e066d213259fe2e Mon Sep 17 00:00:00 2001 From: zhangqian <zhangqian@123.com> Date: 星期四, 25 四月 2024 10:02:01 +0800 Subject: [PATCH] 更改定时任务时区设置 --- service/plc.go | 233 ++++++++++++++++++++++++++++++++++++++-------------------- 1 files changed, 152 insertions(+), 81 deletions(-) diff --git a/service/plc.go b/service/plc.go index 2af5f40..98efc26 100644 --- a/service/plc.go +++ b/service/plc.go @@ -4,6 +4,7 @@ "apsClient/conf" "apsClient/constvar" "apsClient/model" + "apsClient/model/common" "apsClient/pkg/logx" "apsClient/pkg/plc" "apsClient/pkg/plc/apacheplc4x" @@ -13,114 +14,109 @@ "errors" "fmt" "github.com/spf13/cast" - "sync/atomic" + "sync" ) -func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) { - var ( - startAddress int - ipAddr string - ) +// 涓插彛涓嶆敮鎸佸苟琛岃鍐欙紝鎵�浠ラ渶瑕佸姞涓攣锛岄槻姝imeout鍜岃祫婧愪笉鍙敤鎶ラ敊 +var lock sync.Mutex +func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) { if plcConfig.CurrentTryTimes > plcConfig.MaxTryTimes { return plcConfig.CurrentErr } plcConfig.CurrentTryTimes++ - + var targetConfig *model.DevicePlcAddress for _, pc := range plcConfig.Details { if pc.FieldName == fieldType && pc.Channel == channel { - startAddress = pc.StartAddress + targetConfig = pc } } - - if plcConfig.Method == constvar.PlcMethodModbusTCP { - ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - err = WriteHoldingRegister(ipAddr, startAddress, value) - - if err != nil { - logx.Errorf("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error()) - plcConfig.CurrentErr = err - return PlcWrite(plcConfig, fieldType, channel, value) - } - logx.Infof("plc write ok, address: %v, value: %v", startAddress, value) - } else if plcConfig.Method == constvar.PlcMethodSerial { - ipAddr = conf.Conf.Services.Serial - if ipAddr == "" { - return errors.New("conf.Conf.Services.Serial config not set yet") - } - label := fmt.Sprintf("D%d", startAddress) - return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value)) - } - return + return PlcWriteDirect(plcConfig, value, targetConfig) } -func PlcWriteDirect(plcConfig *model.DevicePlc, address int, value interface{}) (err error) { +func PlcWriteDirect(plcConfig *model.DevicePlc, value interface{}, c *model.DevicePlcAddress) (err error) { + lock.Lock() + defer lock.Unlock() var ( ipAddr string ) - defer dealErr(err) + defer func() { + dealErr(err) + }() if plcConfig.Method == constvar.PlcMethodModbusTCP { ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - err = WriteHoldingRegister(ipAddr, address, value) + err = WriteByModbusTCP(ipAddr, c.StartAddress, value, c.Endian, c.Length) if err != nil { - logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error()) + logx.Errorf("plc write failed, address: %v, value: %v, err: %v", c.StartAddress, value, err.Error()) return err } - logx.Infof("plc write ok, address: %v, value: %v", address, value) + logx.Infof("plc write ok, address: %v, value: %v", c.StartAddress, value) + } else if plcConfig.Method == constvar.PlcMethodModbusRTU { + ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) + err = WriteByModbusRTU(plcConfig, c.StartAddress, value, c.Endian, c.Length) + + if err != nil { + logx.Errorf("plc write failed, address: %v, value: %v, err: %v", c.StartAddress, value, err.Error()) + return err + } + logx.Infof("plc write ok, address: %v, value: %v", c.StartAddress, value) } else if plcConfig.Method == constvar.PlcMethodSerial { ipAddr = conf.Conf.Services.Serial if ipAddr == "" { return errors.New("conf.Conf.Services.Serial config not set yet") } - label := fmt.Sprintf("D%d", address) + label := fmt.Sprintf("D%d", c.StartAddress) return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value)) } return } -func PlcReadDirect(plcConfig *model.DevicePlc, address int, dataLength int, valueType constvar.PlcStartAddressValueType) (val interface{}, err error) { +func PlcReadDirect(plcConfig *model.DevicePlc, addressConfig *model.DevicePlcAddress) (val interface{}, err error) { + address, dataLength, endian := addressConfig.StartAddress, addressConfig.Length, addressConfig.Endian + lock.Lock() + defer lock.Unlock() var ( ipAddr string ) - defer dealErr(err) - if plcConfig.Method == constvar.PlcMethodModbusTCP { - ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) - value, err := ReadHoldingRegister(ipAddr, address, dataLength) - if err != nil { - return nil, err - } - switch valueType { - case constvar.PlcStartAddressValueTypeString: - return string(value), nil - case constvar.PlcStartAddressValueTypeInt: - if len(value) == 2 { - val = binary.BigEndian.Uint16(value) - } else if len(value) == 4 { - low16Val := binary.BigEndian.Uint32(value[:2]) - high16 := binary.BigEndian.Uint32(value[2:]) << 16 - val = low16Val + high16 - } else { - logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address) - return nil, errors.New(fmt.Sprintf("unknown int value锛�%v", value)) + defer func() { + dealErr(err) + }() + if plcConfig.Method == constvar.PlcMethodModbusTCP || plcConfig.Method == constvar.PlcMethodModbusRTU { + var value []byte + if plcConfig.Method == constvar.PlcMethodModbusTCP { + ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port) + value, err = ReadByModbusTCP(ipAddr, address, dataLength, endian) + if err != nil { + return nil, err + } + } else { + value, err = ReadByModbusRTU(plcConfig, address, dataLength) + if err != nil { + return nil, err } } - logx.Infof("plc read ok, address: %v, result: %v, dataLength: %v, valueLength: %v", address, val, dataLength, len(value)) - return val, nil + return Convert(value, addressConfig) } else if plcConfig.Method == constvar.PlcMethodSerial { ipAddr = conf.Conf.Services.Serial if ipAddr == "" { return nil, errors.New("conf.Conf.Services.Serial config not set yet") } label := fmt.Sprintf("D%d", address) - return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label) + return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label, dataLength) } return } -func ReadHoldingRegister(ipAddr string, address, length int) ([]byte, error) { +func ReadByModbusTCP(ipAddr string, address, length int, endian constvar.EndianType) ([]byte, error) { if conf.Conf.PLC.Package == constvar.PlcPackageApache { - return apacheplc4x.ReadHoldingRegister(ipAddr, address, length) + var intType string + if endian == constvar.EndianTypeMix { + intType = "UINT" + } else { + intType = "DINT" + } + return apacheplc4x.ReadHoldingRegister(ipAddr, address, length, intType) } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { conn, err := plc.GetModbusConnection(ipAddr) if err != nil { @@ -132,9 +128,23 @@ } } -func WriteHoldingRegister(ipAddr string, address int, value any) (err error) { +func WriteByModbusTCP(ipAddr string, address int, value any, endian constvar.EndianType, length int) (err error) { if conf.Conf.PLC.Package == constvar.PlcPackageApache { - _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value) + var intType string + if endian == constvar.EndianTypeMix { + intType = "UINT" + int32Value := cast.ToInt32(value) + highVal := int32Value / (1 << 16) + lowValue := int32Value % (1 << 16) + _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, lowValue, intType) + if err != nil { + return err + } + _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address+1, highVal, intType) + } else { + intType = "DINT" + _, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value, intType) + } return err } else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { conn, err := plc.GetModbusConnection(ipAddr) @@ -144,19 +154,34 @@ _, err = plc.WriteHoldingRegister(conn, address, value) return err } else { - return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value)) + return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value), string(endian), length) } +} + +func ReadByModbusRTU(plcConfig *model.DevicePlc, address, length int) ([]byte, error) { + rtuConfig := &common.RTUConfig{ + BaudRate: plcConfig.BaudRate, + SerialName: plcConfig.SerialName, + DataBit: plcConfig.DataBit, + StopBit: plcConfig.StopBit, + Parity: plcConfig.Parity, + } + return modbusx.ReadByRTU(rtuConfig, uint16(address), uint16(length)) +} + +func WriteByModbusRTU(plcConfig *model.DevicePlc, address int, value any, endian constvar.EndianType, length int) (err error) { + rtuConfig := &common.RTUConfig{ + BaudRate: plcConfig.BaudRate, + SerialName: plcConfig.SerialName, + DataBit: plcConfig.DataBit, + StopBit: plcConfig.StopBit, + Parity: plcConfig.Parity, + } + return modbusx.WriteByRTU(rtuConfig, uint16(address), cast.ToInt(value), string(endian), length) } func PlcIsConnect() bool { return IsConnect() - //if conf.Conf.PLC.Package == constvar.PlcPackageApache { - // return apacheplc4x.IsConnect() - //} else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection { - // return false - //} else { - // return modbusx.IsConnect() - //} } func dealErr(err error) { @@ -167,32 +192,78 @@ } } -var connectionStatus atomic.Bool - -var failureRemainingOpportunities atomic.Int64 +var connectionStatus sync.Map const ( defaultFailureRemainingOpportunities = 20 ) func IsConnect() bool { - return connectionStatus.Load() + val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) + if !ok { + return false + } + failureRemainingOpportunities := val.(int) + return failureRemainingOpportunities > 0 } func FailureRemainingOpportunitiesDecr() { - newValue := failureRemainingOpportunities.Add(-1) - if newValue <= 0 { - connectionStatus.Store(false) + val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) + if !ok { + return } + failureRemainingOpportunities := val.(int) + if failureRemainingOpportunities > 0 { + failureRemainingOpportunities-- + } + connectionStatus.Store(conf.Conf.CurrentDeviceID, failureRemainingOpportunities) return } func FailureRemainingOpportunitiesReset() { - if failureRemainingOpportunities.Load() < defaultFailureRemainingOpportunities { - failureRemainingOpportunities.Store(defaultFailureRemainingOpportunities) + val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID) + if !ok || val.(int) < defaultFailureRemainingOpportunities { + connectionStatus.Store(conf.Conf.CurrentDeviceID, defaultFailureRemainingOpportunities) + return } - if connectionStatus.Load() == false { - connectionStatus.Store(true) + return +} + +func Convert(rawValue []byte, c *model.DevicePlcAddress) (value interface{}, err error) { + switch c.Type { + case constvar.PlcStartAddressValueTypeString: + return string(rawValue), nil + case constvar.PlcStartAddressValueTypeInt16: + if c.Endian == constvar.EndianTypeLittle { + value = binary.LittleEndian.Uint16(rawValue) + } else { + value = binary.BigEndian.Uint16(rawValue) + } + default: + if len(rawValue) == 2 { + if c.Endian == constvar.EndianTypeLittle { + value = binary.LittleEndian.Uint16(rawValue) + } else { + value = binary.BigEndian.Uint16(rawValue) + } + } else if len(rawValue) == 4 { + if c.Endian == constvar.EndianTypeBig { + value = binary.BigEndian.Uint32(rawValue) + } else if c.Endian == constvar.EndianTypeLittle { + value = binary.LittleEndian.Uint32(rawValue) + } else { + highBts := rawValue[2:] + lowBts := rawValue[:2] + highVal := uint32(binary.BigEndian.Uint16(highBts)) << 16 + lowVal := uint32(binary.BigEndian.Uint16(lowBts)) + value = highVal + lowVal + } + } else { + logx.Errorf("plc read get an unknown int value: %v, address:%v", rawValue, c.StartAddress) + return nil, errors.New(fmt.Sprintf("unknown value锛�%v", rawValue)) + } } + + logx.Infof("plc read ok, address: %v, result: %v, value: %v, c:%+v", c.StartAddress, rawValue, value, c) return } -- Gitblit v1.8.0