From 2d6875c93b25d0b7336c7fa11e066d213259fe2e Mon Sep 17 00:00:00 2001
From: zhangqian <zhangqian@123.com>
Date: 星期四, 25 四月 2024 10:02:01 +0800
Subject: [PATCH] 更改定时任务时区设置

---
 service/plc.go |  295 ++++++++++++++++++++++++++++++++++++++++++----------------
 1 files changed, 211 insertions(+), 84 deletions(-)

diff --git a/service/plc.go b/service/plc.go
index 16c695c..98efc26 100644
--- a/service/plc.go
+++ b/service/plc.go
@@ -4,139 +4,266 @@
 	"apsClient/conf"
 	"apsClient/constvar"
 	"apsClient/model"
+	"apsClient/model/common"
 	"apsClient/pkg/logx"
+	"apsClient/pkg/plc"
 	"apsClient/pkg/plc/apacheplc4x"
+	"apsClient/pkg/plc/modbusx"
 	"apsClient/pkg/plccom"
 	"encoding/binary"
 	"errors"
 	"fmt"
 	"github.com/spf13/cast"
+	"sync"
 )
 
-func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, position int, value interface{}) (err error) {
-	var (
-		startAddress int
-		ipAddr       string
-	)
+// 涓插彛涓嶆敮鎸佸苟琛岃鍐欙紝鎵�浠ラ渶瑕佸姞涓攣锛岄槻姝imeout鍜岃祫婧愪笉鍙敤鎶ラ敊
+var lock sync.Mutex
 
+func PlcWrite(plcConfig *model.DevicePlc, fieldType constvar.PlcStartAddressType, channel int32, value interface{}) (err error) {
 	if plcConfig.CurrentTryTimes > plcConfig.MaxTryTimes {
 		return plcConfig.CurrentErr
 	}
 	plcConfig.CurrentTryTimes++
-
+	var targetConfig *model.DevicePlcAddress
 	for _, pc := range plcConfig.Details {
-		if pc.FieldName == fieldType && pc.Position == position {
-			startAddress = pc.StartAddress
+		if pc.FieldName == fieldType && pc.Channel == channel {
+			targetConfig = pc
 		}
 	}
-
-	if plcConfig.Method == constvar.PlcMethodModbusTCP {
-		ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
-		//conn, err := plc.GetModbusConnection(ipAddr)
-		//if err != nil {
-		//	logx.Errorf("plc write failed, 杩炴帴plc澶辫触: %v", err.Error())
-		//	plcConfig.CurrentErr = err
-		//	return PlcWrite(plcConfig, fieldType, position, value)
-		//}
-		//
-		//result, err := plc.WriteHoldingRegister(conn, startAddress, value)
-
-		//err = modbusx.Write(ipAddr, uint16(startAddress), value)
-
-		_, err = apacheplc4x.WriteHoldingRegister(ipAddr, startAddress, value)
-
-		if err != nil {
-			logx.Errorf("plc write failed, address: %v, value: %v, err: %v", startAddress, value, err.Error())
-			plcConfig.CurrentErr = err
-			return PlcWrite(plcConfig, fieldType, position, value)
-		}
-		logx.Infof("plc write ok, address: %v, value: %v", startAddress, value)
-	} else if plcConfig.Method == constvar.PlcMethodSerial {
-		ipAddr = conf.Conf.Services.Serial
-		if ipAddr == "" {
-			return errors.New("conf.Conf.Services.Serial config not set yet")
-		}
-		label := fmt.Sprintf("D%d", startAddress)
-		return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value))
-	}
-	return
+	return PlcWriteDirect(plcConfig, value, targetConfig)
 }
 
-func PlcWriteDirect(plcConfig *model.DevicePlc, address int, value interface{}) (err error) {
+func PlcWriteDirect(plcConfig *model.DevicePlc, value interface{}, c *model.DevicePlcAddress) (err error) {
+	lock.Lock()
+	defer lock.Unlock()
 	var (
 		ipAddr string
 	)
+	defer func() {
+		dealErr(err)
+	}()
 	if plcConfig.Method == constvar.PlcMethodModbusTCP {
 		ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
-		//conn, err := plc.GetModbusConnection(ipAddr)
-		//if err != nil {
-		//	logx.Errorf("plc write failed, 杩炴帴plc澶辫触: %v", err.Error())
-		//	plcConfig.CurrentErr = err
-		//	return PlcWriteDirect(plcConfig, address, value)
-		//}
-		//result, err := plc.WriteHoldingRegister(conn, address, value)
-
-		//err = modbusx.Write(ipAddr, uint16(address), value)
-
-		_, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value)
+		err = WriteByModbusTCP(ipAddr, c.StartAddress, value, c.Endian, c.Length)
 
 		if err != nil {
-			logx.Errorf("plc write failed, address: %v, value: %v, err: %v", address, value, err.Error())
+			logx.Errorf("plc write failed, address: %v, value: %v, err: %v", c.StartAddress, value, err.Error())
 			return err
 		}
-		logx.Infof("plc write ok, address: %v, value: %v", address, value)
+		logx.Infof("plc write ok, address: %v, value: %v", c.StartAddress, value)
+	} else if plcConfig.Method == constvar.PlcMethodModbusRTU {
+		ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
+		err = WriteByModbusRTU(plcConfig, c.StartAddress, value, c.Endian, c.Length)
+
+		if err != nil {
+			logx.Errorf("plc write failed, address: %v, value: %v, err: %v", c.StartAddress, value, err.Error())
+			return err
+		}
+		logx.Infof("plc write ok, address: %v, value: %v", c.StartAddress, value)
 	} else if plcConfig.Method == constvar.PlcMethodSerial {
 		ipAddr = conf.Conf.Services.Serial
 		if ipAddr == "" {
 			return errors.New("conf.Conf.Services.Serial config not set yet")
 		}
-		label := fmt.Sprintf("D%d", address)
+		label := fmt.Sprintf("D%d", c.StartAddress)
 		return plccom.WritePLC(plccom.DeviceTypeMitsubishi, ipAddr, label, cast.ToInt(value))
 	}
 	return
 }
 
-func PlcReadDirect(plcConfig *model.DevicePlc, address int, dataLength int, valueType constvar.PlcStartAddressValueType) (val interface{}, err error) {
+func PlcReadDirect(plcConfig *model.DevicePlc, addressConfig *model.DevicePlcAddress) (val interface{}, err error) {
+	address, dataLength, endian := addressConfig.StartAddress, addressConfig.Length, addressConfig.Endian
+	lock.Lock()
+	defer lock.Unlock()
 	var (
 		ipAddr string
 	)
-	if plcConfig.Method == constvar.PlcMethodModbusTCP {
-		ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
-		//conn, err := plc.GetModbusConnection(ipAddr)
-		//if err != nil {
-		//	plcConfig.CurrentErr = err
-		//	return PlcReadDirect(plcConfig, address, dataLength, valueType)
-		//}
-		//value, err := plc.ReadHoldingRegister(conn, address, dataLength)
-
-		//value, err := modbusx.Read(ipAddr, uint16(address), uint16(dataLength))
-
-		value, err := apacheplc4x.ReadHoldingRegister(ipAddr, address, dataLength)
-
-		if err != nil {
-			return nil, err
-		}
-		switch valueType {
-		case constvar.PlcStartAddressValueTypeString:
-			return string(value), nil
-		case constvar.PlcStartAddressValueTypeInt:
-			if len(value) == 2 {
-				return int(binary.BigEndian.Uint16(value)), nil
-			} else if len(value) == 4 {
-				return int32(value[2])<<8 + int32(value[3]), nil
-			} else {
-				logx.Errorf("plc read get an unknown int value: %v, address:%v", value, address)
-				return nil, errors.New(fmt.Sprintf("unknown int value锛�%v", value))
+	defer func() {
+		dealErr(err)
+	}()
+	if plcConfig.Method == constvar.PlcMethodModbusTCP || plcConfig.Method == constvar.PlcMethodModbusRTU {
+		var value []byte
+		if plcConfig.Method == constvar.PlcMethodModbusTCP {
+			ipAddr = fmt.Sprintf("%s:%v", plcConfig.Address, plcConfig.Port)
+			value, err = ReadByModbusTCP(ipAddr, address, dataLength, endian)
+			if err != nil {
+				return nil, err
+			}
+		} else {
+			value, err = ReadByModbusRTU(plcConfig, address, dataLength)
+			if err != nil {
+				return nil, err
 			}
 		}
-		logx.Infof("plc read ok, address: %v, result: %v", address, value)
+		return Convert(value, addressConfig)
 	} else if plcConfig.Method == constvar.PlcMethodSerial {
 		ipAddr = conf.Conf.Services.Serial
 		if ipAddr == "" {
 			return nil, errors.New("conf.Conf.Services.Serial config not set yet")
 		}
 		label := fmt.Sprintf("D%d", address)
-		return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label)
+		return plccom.ReadPLC(plccom.DeviceTypeMitsubishi, ipAddr, label, dataLength)
 	}
 	return
 }
+
+func ReadByModbusTCP(ipAddr string, address, length int, endian constvar.EndianType) ([]byte, error) {
+	if conf.Conf.PLC.Package == constvar.PlcPackageApache {
+		var intType string
+		if endian == constvar.EndianTypeMix {
+			intType = "UINT"
+		} else {
+			intType = "DINT"
+		}
+		return apacheplc4x.ReadHoldingRegister(ipAddr, address, length, intType)
+	} else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection {
+		conn, err := plc.GetModbusConnection(ipAddr)
+		if err != nil {
+			return nil, err
+		}
+		return plc.ReadHoldingRegister(conn, address, length)
+	} else {
+		return modbusx.Read(ipAddr, uint16(address), uint16(length))
+	}
+}
+
+func WriteByModbusTCP(ipAddr string, address int, value any, endian constvar.EndianType, length int) (err error) {
+	if conf.Conf.PLC.Package == constvar.PlcPackageApache {
+		var intType string
+		if endian == constvar.EndianTypeMix {
+			intType = "UINT"
+			int32Value := cast.ToInt32(value)
+			highVal := int32Value / (1 << 16)
+			lowValue := int32Value % (1 << 16)
+			_, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, lowValue, intType)
+			if err != nil {
+				return err
+			}
+			_, err = apacheplc4x.WriteHoldingRegister(ipAddr, address+1, highVal, intType)
+		} else {
+			intType = "DINT"
+			_, err = apacheplc4x.WriteHoldingRegister(ipAddr, address, value, intType)
+		}
+		return err
+	} else if conf.Conf.PLC.Package == constvar.PlcPackageApacheLongConnection {
+		conn, err := plc.GetModbusConnection(ipAddr)
+		if err != nil {
+			return err
+		}
+		_, err = plc.WriteHoldingRegister(conn, address, value)
+		return err
+	} else {
+		return modbusx.Write(ipAddr, uint16(address), cast.ToInt(value), string(endian), length)
+	}
+}
+
+func ReadByModbusRTU(plcConfig *model.DevicePlc, address, length int) ([]byte, error) {
+	rtuConfig := &common.RTUConfig{
+		BaudRate:   plcConfig.BaudRate,
+		SerialName: plcConfig.SerialName,
+		DataBit:    plcConfig.DataBit,
+		StopBit:    plcConfig.StopBit,
+		Parity:     plcConfig.Parity,
+	}
+	return modbusx.ReadByRTU(rtuConfig, uint16(address), uint16(length))
+}
+
+func WriteByModbusRTU(plcConfig *model.DevicePlc, address int, value any, endian constvar.EndianType, length int) (err error) {
+	rtuConfig := &common.RTUConfig{
+		BaudRate:   plcConfig.BaudRate,
+		SerialName: plcConfig.SerialName,
+		DataBit:    plcConfig.DataBit,
+		StopBit:    plcConfig.StopBit,
+		Parity:     plcConfig.Parity,
+	}
+	return modbusx.WriteByRTU(rtuConfig, uint16(address), cast.ToInt(value), string(endian), length)
+}
+
+func PlcIsConnect() bool {
+	return IsConnect()
+}
+
+func dealErr(err error) {
+	if err != nil {
+		FailureRemainingOpportunitiesDecr() //鍑忓皯澶辫触鍓╀綑鏈轰細
+	} else {
+		FailureRemainingOpportunitiesReset() //閲嶇疆澶辫触鍓╀綑鏈轰細
+	}
+}
+
+var connectionStatus sync.Map
+
+const (
+	defaultFailureRemainingOpportunities = 20
+)
+
+func IsConnect() bool {
+	val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID)
+	if !ok {
+		return false
+	}
+	failureRemainingOpportunities := val.(int)
+	return failureRemainingOpportunities > 0
+}
+
+func FailureRemainingOpportunitiesDecr() {
+	val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID)
+	if !ok {
+		return
+	}
+	failureRemainingOpportunities := val.(int)
+	if failureRemainingOpportunities > 0 {
+		failureRemainingOpportunities--
+	}
+	connectionStatus.Store(conf.Conf.CurrentDeviceID, failureRemainingOpportunities)
+	return
+}
+
+func FailureRemainingOpportunitiesReset() {
+	val, ok := connectionStatus.Load(conf.Conf.CurrentDeviceID)
+	if !ok || val.(int) < defaultFailureRemainingOpportunities {
+		connectionStatus.Store(conf.Conf.CurrentDeviceID, defaultFailureRemainingOpportunities)
+		return
+	}
+	return
+}
+
+func Convert(rawValue []byte, c *model.DevicePlcAddress) (value interface{}, err error) {
+	switch c.Type {
+	case constvar.PlcStartAddressValueTypeString:
+		return string(rawValue), nil
+	case constvar.PlcStartAddressValueTypeInt16:
+		if c.Endian == constvar.EndianTypeLittle {
+			value = binary.LittleEndian.Uint16(rawValue)
+		} else {
+			value = binary.BigEndian.Uint16(rawValue)
+		}
+	default:
+		if len(rawValue) == 2 {
+			if c.Endian == constvar.EndianTypeLittle {
+				value = binary.LittleEndian.Uint16(rawValue)
+			} else {
+				value = binary.BigEndian.Uint16(rawValue)
+			}
+		} else if len(rawValue) == 4 {
+			if c.Endian == constvar.EndianTypeBig {
+				value = binary.BigEndian.Uint32(rawValue)
+			} else if c.Endian == constvar.EndianTypeLittle {
+				value = binary.LittleEndian.Uint32(rawValue)
+			} else {
+				highBts := rawValue[2:]
+				lowBts := rawValue[:2]
+				highVal := uint32(binary.BigEndian.Uint16(highBts)) << 16
+				lowVal := uint32(binary.BigEndian.Uint16(lowBts))
+				value = highVal + lowVal
+			}
+		} else {
+			logx.Errorf("plc read get an unknown int value: %v, address:%v", rawValue, c.StartAddress)
+			return nil, errors.New(fmt.Sprintf("unknown value锛�%v", rawValue))
+		}
+	}
+
+	logx.Infof("plc read ok, address: %v, result: %v, value: %v, c:%+v", c.StartAddress, rawValue, value, c)
+	return
+}

--
Gitblit v1.8.0